| The GracePortâ„¢ DSX R53, R54, & R55 Series Crossover Switches are a family of programming interfaces for PanelView/AB Serial PLC’s(1.) Systems. These products are sold as complete kits which include: --Qty (2) Interface Cables (PLC to DSX, & PanelView to DSX) --Programming Cable --Pre-configure DSX PCB with “Pinout Stations” to for 100% flexibility --GracePort DSX Assembly with 120 VAC Outlet The DSX is “non-electronic” and requires no software or special communications “box”. The generic version of this product is available as an “R49”. |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Installation Instructions: 1.) Install the DSX Interface on the outside of the enclosure. 2.) Install the appropriate cables from the PanelView and PLC to the DSX. 3.) For programming, depress the “RUN/PROGRAM” maintained switch, which disconnects the “RUN” connections to allow for programming. In most applications, use a standard serial extension cable from the port on the front of the GracePort® . 4.) Once programming is completed, REMOVE THE PROGRAMMING CABLES, depress the move the maintained switch on the front of the GracePort® . to the extended “ RUN” position. NOTE: Remove programming cables when switching to/from RUN Mode |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| (1) Applicable Devices: This product is designed for use with PanelView 300-1400 and 300 Micro, Most Allen-Bradley serial PLC's: SLC 5/03, 5/04, 5/05 (Channel 0); ControlLogix (Channel 0); MicroLogix 1000, 1200, 1500LSP (8MDIN Channel); MicroLogix 1500LRP (Channel 0); CompactLogix (Channel 0); FlexLogix (Channel 0) |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Designed to offer a convenient "through-the-door" programming interface for MicroLogix/PanelView Systems. In most cases, the serial ports on these devices are used for programming and runtime communication. Without the DSX, programming involves: opening the panel door, unplugging the RUN cable, then plugging in the programming cable. The GracePort® DSX Crossover Switch in installed between both devices and allows the user to program either the MicroLogix (Device#1) or the PanelView (Device#2) from outside the control panel. When programming is completed, the user returns the interface to "RUN" mode. |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Click Here for PDF of complete Pinout Configurations for R53, R54 & R55 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| How it works? Program mode: The DSX disconnects the “RUN” connection (all 9 pins) between both devices. This makes both the DEVICE#1 and the DEVICE#2 programming ports fully accessible to the user from the on the outside of the panel. Run Mode: The “RUN” connection is restored, thereby allowing both devices to communicate. For applications assistance, please call us at 1-800-280-9517 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| (1) Applicable Devices: This product is designed for use with PanelView 300-1400 and 300 Micro, Most Allen-Bradley serial PLC's: SLC 5/03, 5/04, 5/05 (Channel 0); ControlLogix (Channel 0); MicroLogix 1000, 1200, 1500LSP (8MDIN Channel); MicroLogix 1500LRP (Channel 0); CompactLogix (Channel 0); FlexLogix (Channel 0) |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() |
![]() |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||